VI-TEX has different versions for single axis and triaxial. You can following below feature information to choose the suitable one:
1. A specific directions of vibration, can support up to three-axis.(horizontal (front and back, left and right) and vertical (up and down)).
2. A variety of sensitivity options. Although in different fields, it also can capture the vibration signal from small to large.
3. Support the fuction for converting signal characteristics such as displacement, velocity or acceleration. Since vibration is composed by a multiple complex frequency, frequency, amplitude and phase can all be used for trigger settings. 。
Signal | Description |
---|---|
Speed | It's suitable for checking the condition of rotating machinery. The frequency band is from 10 to 1000 Hz, which is the most used unit of measurement. |
Acceleration | It's used to measure higher frequency vibrations such as bearings or gearboxes. It is suitable for monitoring vibrations from generate pulses, like bearing wear, scratches or debris. |
Displacement | Indicates the fluctuation range of vibration. It's suitable for measuring unbalance vibration like fans, blowers, etc. The frequency band is very low, the range is from 10 Hz to hundreds of Hz. |
If the size is too small or have no installation platform, we can not installed. But if the object is already fixed on another platform, we acan also install it on the platform. Or choosing a customized installation base.
Machines without a fixed operating mode cannot establish the trigger values or provide predictive indicators through vibration detection. If you need to measeue it, it need to use a long time and observe the short, medium and long term aging curve to provide special services.
VI-TEX can provide indicators of current mechanical operating conditions and health assessments. If you need to achieve anti-vibration effects, you need to purchase other anti-vibration equipment.
VI-TEX is designed for long-term monitoring and providing high-speed edge computing capabilities. It can greatly save the burden of other equipment. Therefore, it must be connected to the power and the battery is only support special needs.